(Two-hour restrained or unrestrained beam.). Resilient channels applied perpendicular to 2” x 10” wood joists 16” (406 mm) o.c. with 1” (25 mm) Type S drywall screws 12” (305 mm) o.c. placed 2″ back on either side of horizontal joints. U428 October 13, 2015 Nonbearing Wall Rating — 2 Hr at intermediate studs when applied vertically to studs. Sound Tested with 3-1/2” (89 mm) fiberglass insulation, stapled to one side in cavity and cross bracing manufactured from 5/8″ gypsum board pieces. Underwriters Laboratories of Canada ULC 7 Underwriters Road Toronto, Ontario, Canada M1R 3B4 www.ulc.ca National Research Council of Canada NRCC Institute for Research in Construction 1200 Montreal Road Ottawa, Ontario, Canada K1A OR6 www.irc.nrc-cnrc.gc.ca Underwriters Laboratories Inc. UL 333 Pfingsten Road Northbrook, Illinois, U.S.A. 60062-2096 www.ul.com Gypsum Association GA … 5/8” (15.9 mm) ToughRock® Fireguard X® (per UL U421 only)Products or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically or horizontally to one side of 2-1/2” (64 mm), 25-gauge (18 mils) steel studs 24” (610 mm) o.c. with 1-5/8” (41 mm) cement coated nails spaced 7” (178 mm) o.c. Green Glue Compound (.66 tubes/sheet) 5/8" Drywall. Report OL05-1046.pdf. GP Gypsum makes no representation or warranty, express or implied, concerning this information and specifically disclaims any implied warranty of fitness for a particular use. 2.5m : 21.2 kW/m2 . 5/8” (15.9 mm) ToughRock® Fireguard X™ or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically (per ULC W301) or horizontally (UL U305) to each side of 2” x 4” wood studs 16” (406 mm) o.c. 5/8” (15.9 mm) ToughRock® Fireguard X® or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically (or horizontally to each side of double row of 2” x 4” wood studs 16” (406 mm) o.c. Resilient channels applied perpendicular to 2” x 10” wood joists 16” (406 mm) o.c. with 1” (25 mm) Type S screws 12” (305 mm) o.c. The purpose of this guide is to summarize fire and sound data for steel floor, wall and roof assemblies that are relevant to residential and light commercial construction. 1-1/2″ Fiberglass sound insulation friction fit in stud space. longer than distance to interior face of steel studs. Base layer attached with 1-7/8” (48 mm) 6d cement coated nails 6” (152 mm) o.c. 3-1/2” (89 mm) corrosion resistant 20-gauge (33 mils) steel studs 24” (610 mm) o.c. ASTM E119 or CAN/ULC-S101 standard tests were used to rate . Standard for Industrial Control Panels (Ed. We also offer two different types of subscriptions: a one year and a three year. 3” (76 mm) mineral fiber insulation, 2 pcf (32 kg/m3), friction fit in stud space. Horizontal bracing required at mid height. at joints and intermediate joists. Vertical joints midway between studs. Load Bearing. Sound tested with 2-1/2” (64 mm) fiberglass insulation. Ultimately, the design and detailing of the project, assembly or system is the responsibility of a professional, and all projects must comply with applicable building codes and standards. Plywood end joints staggered 48” (1219 mm). Interior Side: 5/8” (15.9 mm) ToughRock® Fireguard X® Products or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically or horizontally to studs with 1-7/8” (48 mm) 6d coated nails 7” (178 mm) o.c. at intermediate studs when applied vertically to framing, or 8” (203 mm) o.c. OC. 20-gauge (30 mils) galvanized wire ties attached to each stud with 2-3/8” (60 mm) 8d coated nails, located at every sixth course of bricks. Algeria. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard X® Products or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied perpendicular to joists through base layer with 1-7/8” (48 mm) Type W or S screws 12” (305 mm) o.c. with 1” (25 mm) Type S drywall screws 12” (305 mm) o.c. at edges and ends and 12” (305 mm) o.c. Face layer attached with 1-5/8” (41 mm) Type S-12 bugle head screws spaced 12” (305 mm) o.c. at vertical joints and 12” (305 mm) o.c. with 1” (25 mm) Type S screws 24” (610 mm) o.c. 6 CGC Fire-Resistant Assemblies Test Certification Test Conditions and Fire and sound tested assemblies listed in this Selector are based on characteristics, properties and performance Certification of materials and systems obtained under controlled test conditions as set forth in the appropriate ULC and ASTM Standards in effect at the time of test. when insulation is used or 16” (406 mm) o.c. One layer of 1″ x 24″ DensGlass Shaftliner or ToughRock Shaftliner inserted between 2-1/2″ floor and ceiling runners of minimum 2-1/2″ C-T, C-H or I studs between panels. at joints and floor and ceiling runners and 12” (305 mm) o.c. with 1” (25 mm) Type S screws 16” (406 mm) o.c. APPROVALS. End joints secured to both resilient channels. 44 S641:2017 Standard For Factory-built Chimney Connectors And Wall Pass-through Assemblies - Third Edition 2017 ULC 45 S717.1-2017 Standard For Flat Wall Insulating Concrete Form (Icf) Units _ Material Properties - Second Edition 2017 ULC with 6d coated nails, 1-7/8” (48 mm) long, 0.0915” (2 mm) shank, 1/4” (6 mm) heads, 12” (305 mm) o.c. (Limited load-bearing), 5/8” ToughRock® Fireguard C® gypsum board or 5/8” DensArmor Plus® Fireguard C® gypsum panel (UL G505 only) applied perpendicular to rigid furring channels 24” (610 mm) o.c. 35 kW/m2) R-value of tested assembly . Face layer attached with 1-5/8” (41 mm) Type S corrosion resistant bugle head screws spaced 8” (203 mm) o.c. Founded in 1950 by Sam Bailey, Bailey Metal Products Ltd. is a family owned and operated Canadian company. 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panels applied perpendicular to 2” x 10” wood joists 16” (406 mm) o.c. These requirements are based on the following SCC Requirements and Guidance documents: a) … when applied horizontally to studs and 8” (203 mm) at vertical and bottom edges and 12” (305 mm) o.c. legs, formed from min No. ... ULC W313 C D A 38 x 89 mm [2" x 4"] wood studs 406 mm [16"] o.c. 87.8 kB. 20-gauge (33 mils) hexagonal steel mesh fitted between middle and face layers of gypsum board along bottom and extending 1-1/2” (38 mm) onto sides. to studs and track and 1-1/2” (38 mm) Type G drywall screws 24” (610 mm) o.c. Face Layer: Attached with 2-1/4” (57 mm) Type S drywall screws 12” (305 mm) o.c. Interior: Two layers 5/8” (15.9 mm) DensArmor Plus® Fireguard® or 5/8” (15.9 mm) ToughRock® Fireguard X® applied horizontally or vertically to framing. All rights reserved. Trusses have a minimum depth of 12” (305 mm). 5/8” (15.9 mm) ToughRock® Fireguard X® or 5/8” (15.9 mm) DensArmor Plus® Fireguard® gypsum panels applied vertically to each side of 3-5/8” (92 mm) steel studs 24” (610 mm) o.c. Interior: Two layers 5/8” (15.9 mm) DensArmor Plus® Fireguard® or 5/8” (15.9 mm) ToughRock® Fireguard X® applied vertically to framing. with 1-7/8” (48 mm) 6d coated nails 8” (203 mm) o.c. with 21-gauge (37 mils) galvanized steel hanger straps fastened to sides of joists. Fire-resistance rated assemblies. Nonbearing Wall Ratings) - Proprietary channel shaped studs, 3-5/8 in. Height of flame on wall above opening (max. Hilti develops products to create openings in wall and floor assemblies (drilling or core rigs), and products to secure the penetrating items through these assemblies (installation systems, anchors). at studs and 1-1/2″ Type G screws 16″ o.c. Click this link to go to EMSEAL’s Index on the UL Online Certifications Directory. Stagger vertical joints 16” (406 mm) o.c. Third Layer: Attached to sheet-metal angles with 1” (25 mm) long, self-drilling, self-tapping screws spaced vertically 12” (305 mm) o.c. with 18-gauge (43 mils) wire 15” (381 mm) o.c. Stagger vertical joints 24″ (610mm) o.c. Face layer attached to base layer only with 1-1/2” (38 mm) Type G drywall screws 12” (305 mm) o.c. with 1” (25 mm) Type S-12 drywall screws 12” (305 mm) o.c. Sound tested with 1-1/2” (38 mm) fiberglass insulation. Details of UL and ULC listings for fire rated floor, wall and truss assemblies can be downloaded from the website of UL and ULC by using the alphanumeric fire identifier within a keyword search. 3” (76 mm) glass fiber insulation 0.90 pcf (14.4 kg/m3) in joist space stapled to subfloor. FIRE SAFETY CAUTION – Passing a fire test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fire resistance or protection rating and, therefore, as acceptable for use in certain fire rated assemblies/systems, does not mean that either a particular assembly/system incorporating the product, or any given piece of the product itself, will necessarily provide one-hour fire resistance, two-hour fire resistance, or any other specified fire resistance or protection in an actual fire. 1-1/2” (38 mm) fluted steel deck units welded to top of beam and supporting minimum 2-1/2” (64 mm) concrete. Curtain Wall Assembly – The curtain wall assembly shall incorpora te the following construction features: A. (124, 156, 187 and 219 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m 3) structural concrete for 1, 2, 3 and 4 Hr rated assemblies, respectively. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. in field. Assembly Tests ANSI/UL10C-09 or ANSI/NFPA 252-2008 CAN/ULC-S104-10 Fire Door Frame and Transom Frame Design UL Subject 63-03 CAN/ULC-S105-09 Fire Window Assembly Tests ANSI/UL9-09 or ANSI/NFPA 257-2007 CAN/ULC-S106-15 Fire Door and Window Assembly Installation ANSI/NFPA 80-2010 ANSI/NFPA 80-2007 ULC W301 allows vertical application only. Four layers of 5/8” (15.9 mm) ToughRock® Fireguard C® gypsum board or 5/8” (15.9 mm) DensArmor Plus® Fireguard C® covering W10 x 49 (metric W250 x 73) steel column. Face Layer: 5/8” (15.9 mm) ToughRock Fireguard X or DensArmor Plus Fireguard gypsum panels applied vertically or horizontally to same side of studs with 1-5/8” (41 mm) Type S drywall screws 12” (305 mm) o.c. 4” (102 mm) maximum foam-on-plastic thickness. Joints staggered. Base Layer: Attached with 1” (25 mm) Type S drywall screws 24” (610 mm) o.c. One layer 1″ x 24″ (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner panel inserted between 2-1/2″ floor and ceiling J runners with H section of 2-1/2″ (64 mm), C-T, or C-H studs between panels. Resilient channel 24” (610 mm) o.c. Base layer attached with 1” (25 mm) Type S corrosion resistant bugle head screws 16” (406 mm) o.c. 1” (25 mm) corner bead applied each corner with 1-3/8” (35 mm) 4d coated nails 12” (305 mm) o.c. Face layer 5/8″ (15.9 mm) ToughRock® Fireguard X® Products or 5/8″ (15.9 mm) DensArmor Plus® Fireguard® gypsum panels installed vertically to studs with 1-58″ Type S screws 24″ o.c. Rating is 1 h when combustible members are framed into wall. 5/8” (15.9 mm) ToughRock® Fireguard X™ or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum board applied vertically to each side of 2” x 4” wood studs 24” (610 mm) o.c. The test measures flame spread and material temperatures using thermocouples and with 1-7/8” (48 mm) 6d coated nails spaced 7” (178 mm) o.c. Joint compound 1/16” (2.0 mm) thick applied over corner bead. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard X™ or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically to each side with 1-5/8” (41 mm) Type S drywall screws 8” (203 mm) o.c. Lateral bracing on both sides of the wall not less than 5 feet on center vertically. Horizontal bracing required at mid height. Polymer-based exterior insulation and finish system applied over sheathing. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard® gypsum board applied vertically to each side. UL, 1 hour U3411, U3761, W3131 5/8” 11-1/4” ES MR 65 est. Second Layer: Attached to steel studs with 1-5/8” (41 mm) long self-drilling, self-tapping screws spaced vertically 24” (610 mm) o.c. Joists supporting 28-gauge (15 mils) corrugated steel deck and 2-1/2” (64 mm) concrete slab measured from the bottom of the flutes. Face layer offset 24″ from base layer joints. Interior Wood-framed Wall Alternate Assemblies Note that various assemblies can achieve the desired UL/ ULC fire rating and/or acoustic performance (STC) for this application. mm, fabricated from minimum 0.53 mm galvanized steel. Designed to separate a room from structure or space above and composed of 1” (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner panels supported by 2-1/2” (64 mm), 4” (102 mm) or 6” (152 mm) C-T studs and three layers of 1/2” (12.7 mm) ToughRock® Fireguard C® or 1/2” (12.7 mm) DensArmor Plus® Fireguard C® gypsum panels. Joints staggered 24″ on Opposite Sides. Brackets formed of steel channels spaced 24” (610 mm) o.c. Third Layer: 1/2” (12.7 mm) ToughRock Fireguard C gypsum board or 1/2” (12.7 mm) DensArmor Plus Fireguard C gypsum panel applied vertically to each side with joints offset 8” (203 mm) from studs and staggered 24” (610 mm) each side, attached to studs with 2” (51 mm) Type S drywall screws 24” (610 mm) o.c. Screws spaced 1/2” (12.7 mm) and 6” (152 mm) from side joints and 12” (305 mm) o.c. End joints located midway between joists and staggered between rows. 1Load bearing wall assembly. with 1” (25 mm) corrosion resistant bugle head screws 8” (203 mm) o.c. Sound Tested with 3-1/2” (89 mm) fiberglass insulation. Resilient channels 24” (610 mm) o.c. All design details enhancing the structural integrity of the wall assembly, including the axial design load of the studs, shall be as specified by the steel stud designer and/or producer, and shall meet the requirements of all applicable local code agencies. (NLB). Joints offset 24″ from base layer joints. Detail No. 5/8” (15.9 mm) gypsum board pieces 12” (305 mm) long x 4-1/2” (114 mm) wide located at 1/3 points used as cross braces fastened to stud pairs with three 1” (25 mm) Type S drywall screws at each end of brace. Wall : 5/8" Drywall. Face Layer: 5/8” (15.9 mm) ToughRock® Fireguard X® Products or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically or horizontally to studs with 2-3/8” (60 mm) 8d coated nails 8” (203 mm) o.c. Joints staggered. Second Layer: 1/2” (12.7 mm) ToughRock Fireguard C gypsum board or 1/2” (12.7 mm) DensArmor Plus Fireguard C  gypsum  panels applied vertically to each side with joints 8” (203 mm) from studs staggered 24” (610 mm) each side attached to studs with 1-5/8” (41 mm) Type S drywall screws 24” (610 mm) o.c. to open web steel joists 24” (610 mm) o.c. Face layer – 5/8” (15.9 mm) ToughRock® Fireguard X® (per UL U421 only)Products or 5/8” (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically or horizontally to studs with 2-3/8” (60 mm) Type S drywall screws 8” (203 mm) o.c. on separate plates 1” (25 mm) apart with 1-7/8” (48 mm) 6d coated nails 7” (178 mm) o.c. Runners attached to structural supports with steel fasteners located not greater than 50.8 mm from ends and not greater than 610 mm OC. Upper channels secured to steel deck units with 1/2” (12.7 mm) Type S pan-head screws spaced 12” (305 mm) o.c. 1/2″ (12.7 mm) ToughRock® Fireguard 45® gypsum board applied vertically or horizontally to each side of 2” x 4” wood studs 24” (610 mm) o.c. In the event of an actual fire, you should immediately take any and all actions necessary for your safety and the safety of others without regard for any fire rating of any product or assembly/system. (NLB). STANDARD METHOD OF FIRE TEST OF EXTERIOR WALL ASSEMBLIES ULC Standard CAN-ULC-S134-13-REV1. 3” mineral or glass fiber insulation in stud space. Face layer 5/8” (15.9 mm) DensArmor Plus Fireguard or 5/8” (15.9 mm) ToughRock® Fireguard X® Products applied horizontally to studs with 8d coated nails, 2-3/8” (60 mm) long, 0.113” (3 mm) shank, 9/32” (7 mm) heads, 8” (203 mm) o.c. Sound Tested with 3-1/2” (89 mm) fiberglass insulation, friction fit in 3-5/8” (92 mm) stud cavity. shall be 1” (25 mm) by 18-gauge (43 mils) steel straps attached to each side or channel bracing attached to each stud with a clip angle. Horizontal bracing required at mid height. and with 1-1/2” (38 mm) Type G drywall screws 12” (305 mm) o.c. with 5d nails 1-5/8” (41 mm) long, 0.099” (2.5 mm) shank, 1/4” (6 mm) heads, 6” (152 mm) o.c. Horizontal joints staggered not less than 6” (152 mm) between layers. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies.
Voter Demographics Uk, Pray The Devil Back To Hell 123movies, Haba Musical Toys, Taylor Ann Green Family, Folk Devils And Moral Panics Review, Foreign Correspondent Reporters,