& Wire Braid. We have been doing this for companies since 1947. The seals have been tested to IP66 and meet the requirements of the standard. Call Us +27 11 955 2190 "To do what we do, better than any competitor on the world market and to do it honestly" ‘A’ Overall Dia. Gland Selection Table: 600 / 1000v stranded copper conductors pvc insulated with steel wire amour and PVC sheathed overall. Hence, the required cable shall able to carry minimum 15A current. The popular steel wire armour cable gland consists of four parts: The outer nut, the inner, the cable gland bush (with rotary cone) and the locknut as shown below : The glands are also available with a loose cone : Cable gland selection chart: Cable Size (mm 2) Recommended Gland Size for Cable Size/Number of Cores Number of Cores Overall Diameter (mm) • Continuous operating tempera-ture range of -60°C to +130°C. Gland Details H Cable Glands Industrial Glands Gland Details Ref: BARRX/04/07 B A D E F C Gland References & Thread Sizes Cable Dimensions mm Gland Dimensions mm Basic Size Metric NPT Max. The range also includes locknuts, earth tags and PVC shrouds. The seal is manufactured from a silicone material, has LSFZH properties, is ozone and oil resistant and is suitable for use at both high and low temperatures. Cable Gland Type Size Thread Material (Optional) 501/421 C M32 Brass S 501/421 C 1 ¼ " NPT Brass S Cable gland size chart all core. 0000001415 00000 n 0000027006 00000 n 0000034151 00000 n 21 400 sq.mm*4 core 88MM. 0000001595 00000 n Oversize Cable Glands and Increased Safety Cable Glands 23 Mining Gland Features 24 653/Universal Group 1Technical Data 25 653/T Group 1Technical Data 26 623 Group 1 27 Stopping Plug and Flanges Group 1 28 Adaptors and Reducers Group 1 29 Mining Glands andAccessories 24 - 29 We can supply you with the right sizes, types, and quantities of product you need to keep you on schedule and your management happy. We use this type for SWA armoured cables. What’s more, it will also facilitate the fast accomplishment of your installation. We have a proud heritage of over 60 years of manufacturing cable glands in the UK for industrial and hazardous areas. Outdoor cable glands contain either one seal or two seals. The Comprehensive Range Covers Sizes from: M12 / 12.0 mm (3.0–6.5 mm cable range) up to M63 / 63.0 mm (34.0–44.0 mm cable range) Technical Features Anti vibration cap Cable Gland Selection Table Max Max Min Max Max 20S M20 10.0 11.7 16.1 0.9 1.25 24.0 RRPL-BW20S Cable size = 1.5 x 10 =15 A. All of our cable glands have the waterproof functions IP68 grade, it was applied widely in electrical equipment, … Cable Gland Electrical Cable Size Chart Pdf picture published and submitted by Admin that saved in our collection. 0000029780 00000 n 15 185 sq.mm*3 1/2 core 50MM. GLANDS ACCESSORIES The recommendations above are given in good faith but the dimensions of cables may vary with manufacturing tolerances and we advise that the cable diameter is measured where possible before purchasing components. 0000037457 00000 n 18 300 sq.mm*3 1/2 core 70MM. ISO fine thread in cable glands took place on 01.01.2000. 0000005725 00000 n CABLE SPEC. ² Sizes Os and O are available with an M16 thread size. We advise that the most accurate way to select your gland is based on the measurement of your cable. 0000005381 00000 n ‘B’ Braid Wire Dia. Here at Hawke International, our cable glands are engineered with the upmost robustness without compromising ease of installation and safety. x�b``�f``>� }L���Y8008 �JC1�2?�$&� !�h,�h0:�8D84�l�dvt�:��qř���#W"��!��(�T�wb�?���?�^��������F�LQ����4TZ��8�x��+_fH*��s���t��K���޲�`�F� �po����嵒�u+&o[���]�+�׵��N+���NI�D�-z�#X�QKu{ac�@�b��Y|�f��W�����a�fz? SWA Cable Gland Chart: Cable Size: 1 Core: 2 Core: 3 Core: 4 Core: 5 Core: 7 Core: 12 Core: 19 Core: 27 Core: 37 Core: 48 Core: 1.5mm² - 20S 20S 20S 20S 20 25 25 32 32 32 2.5mm² - 20S 20S 20S 20 20 25 25 32 40 40 4.0mm² - 20S 20S 20 20 20 25 32 40 40 50 6.0mm² - 20 20 20 20 25 - - - - - 10.0mm² - … Cable Glands may be used on all types of electrical power, 0000001997 00000 n This catalogue contains a large selection of metric cable glands Ex cables and cable entries for use in hazardous areas. Note that, we did not include the voltage drop across the cable. resistance. Over Conductors Max. 0000006060 00000 n 0000034435 00000 n %PDF-1.4 %���� of Cores: Approx. Note: For HV cable, we cannot use cable gland. 6 0 obj <> endobj xref 6 30 0000000016 00000 n This type of glands are used in dry indoor areas and used with all type of single wire armoured cables, plastic or rubber sheathed cables. ITC’s cable glands are available in an array of styles and colours, and in the most popular threads including NPT, PG, Metric and BSP (PF or Gas). 1kV XLPE ARMOURED CABLES TO BS 5467 Dia. 20 400 sq.mm*3 1/2 core 82MM. If you need a non-stock item, don't worry. CABAC stock a diverse range of cable glands, including nylon and metal glands as well as metric thread and PG thread options. We will make it for you. cable glands and locknuts are designed with anti-vibration top caps. H�쓽��0��������DB44�k)��{tJL��. 0000002928 00000 n They are used throughout all industries in conjunction with cable and wiring used in electrical, instrumentation, control and automation systems. The glands have a wide clamping range. For sizes 32mm and above each kit includes 1 of each component. 0000002963 00000 n 0000000896 00000 n Http Www Sourceiex Com Catalogs Chapter 2013 20ex 20wiring 20methods Pdf. 0000003587 00000 n of Conductors Inner Sheath Dia. For O size with M16 thread, the maximum cable outer sheath diameter is 10.9mm Ordering Information Format for ordering is as follows: Alternative Seal (S), add suffi x S to ordering information. Cable Gland Electrical Cable Size Chart Pdf have a graphic associated with the other. �����zX�g�P[����+�KC�ǏUj�� 5]�L.+=��020L�A�:1+Â>�8�e� g�\ endstream endobj 7 0 obj <> endobj 8 0 obj <> endobj 9 0 obj <>/ColorSpace<>/Font<>/ProcSet[/PDF/Text/ImageC]/ExtGState<>>> endobj 10 0 obj <> endobj 11 0 obj <> endobj 12 0 obj <> endobj 13 0 obj [/ICCBased 23 0 R] endobj 14 0 obj <>stream We should have to use shroud for ingress protection. 0000001179 00000 n No. of cores indoor outdoor cleat size bw gland cw gland 2 20s 20/16 5 3 20s 20/16 6 4 20s 20s 6 7 20s 20s 7 12 20 20 8 19 25 25 10 27 32 32 11 37 32 32 12 48 32 32 14 2 20s 20s 6 3 20s 20s 6 4 20s 20s 6 7 20 20 7 12 25 25 9 19 25 25 11 27 32 32 12 37 32 32 14 48 40 40 16 2 20s 20s 6 0000004253 00000 n 0000037380 00000 n 0000029458 00000 n Download Pratley Product pricelists, cable gland selections charts, product certifications, hazardous location info and more. The first dimensional analysis is related to the sizes of the cable glands, depending on the diameters of the cables required. 0000004576 00000 n Hazardous Area Cable Glands This arrangement offers IP66, IP67, IP68 (30 metres for 7 days), NEMA 4X and Deluge (DTS01) Ingress Protection. (BS 6346 : 1997) Cable Size … These glands are designed to accommodate a wide variety of cable diameters, from approximately 2mm-63mm / 0.08-2.50”, and most models are IP68 rated, meaning that they can be immersed in Electrical & Electronic; Cable Glands; Cable Glands. 14 150 sq.mm*3 1/2 core 50MM. 0000001102 00000 n ‘C’ Approx. Look at the Cable current rating Chart, 2.5Sqmm copper has the ability to carry 18 Amps, hence 2.5sqmm is suitable for 5.5kW/7.5HP motor. Gland Selection Guide . • The Cable Gland provides mechani-cal cable retention, and electrical continuity via armor termination. The following list should be used to ensure that the cable gland selected is correct: 0000037055 00000 n wire and cable, coaxial cables, heat shrinkable products, and fi ber optic products. 0000003892 00000 n Sealing technique - Unique Compensat- 0000032538 00000 n 0000004982 00000 n For the incoming feed cable, it’s necessary a double seals cable gland, type REVD3, size M32, with outer armor sealing ring range of 24 ÷ 31mm and inner armor sealing ring range of 18 ÷ 24mm. Look at the double compression cable gland table, we have given you the Brass Cable Gland … cable gland & cable cleat selector chart conductor size (mm squared) no. Double Compression Cable Gland Chart: Double compression cable glands are increasing the mechanical support for the cable. Cable Glands & Adapters Mencom Corporation TEL: 770-534-4585 www.mencom.com Cable Glands: NPT Threads Standard Plastic Cable Glands Mencom cable glands are easy to use and provide a good strain relief and water tight seal for round cables. 19 400 sq.mm*3 core 75MM. CABLE GLAND SIZE CHART ; Conductor Size (mm 2): No. 16 185 sq.mm*3 core 57MM. 1 Kopex-Ex Product Catalogue | LIT-166GBR 04/15 1 5 9 13 3 7 11 15 17 2 6 10 14 4 8 12 16 18 Introduction Flexible conduit systems Cable glands Thread convertors, stopping plugs & accessories CABLE GLANDS ARE MECHANICAL CABLE ENTRY DEVICES, WHICH CAN BE CONSTRUCTED FROM METALLIC OR NON-METALLIC MATERIALS OR A COMBINATION OF BOTH. 0000002670 00000 n There is clear scope for the electrical cable size and gland size in that size chart, you could find suitable size gland for your cables. trailer <]>> startxref 0 %%EOF 35 0 obj <>stream Gland Kits Available Cable Gland Kit for use with all types of SWA cable, including 2 Brass Glands, 2 Steel Locknuts, 2 Brass Earth Tags and 2 PVC Shrouds for sizes up to and including 25mm. For example: PG7 cable gland with the cable clamping range 3-6.5mm, that means the electrical cable diameter size must be in this range, otherwise, you should change another size to match it. This assists in areas where vibration could be a problem, although the cap when tightened is locked it can be un-screwed and re-tightened. 22 600 sq.mm*3 1/2 core 100MM. 0000032878 00000 n 17 240 sq.mm*3 1/2 core 63MM. 0000006595 00000 n Nominal Cable Size Nominal Gland Dia (mm) Gland Reference (mm) Dia (mm) Reference 17.5 CW20AL-PK 300 35.6 CW40AL-PK 20.2 CW20AL-PK 400 40.4 CW50SAL-PK 22.3 CW25AL-PK 500 44.2 … As the cable gland is tightened it compresses the seal, which grips the cable. Cable gland size ranging from 12mm to 100mm for the normal instrument, there are single compression and double compression for different customer’s requirements. Brass indoor gland suitable for single wire armored, plastic or rubber sheathed cable. In order to avoid such calculation, we have prepared cable gland size chart for 1 core, 2 core, 3 Core, 3.5 core, 4 core, 5core, 7 core, 10 core, 12 core, 19 core, 27core, 37 core and 48 core cable. The cable glands are rated up to IP 68-5 BAR (comparable to NEMA 6P). Use the table below to assist in gland size selection for your cable. Materials: • Standard Cable Gland: Brass with Nickel-Plated threaded entry • Seal: Solo LSF • Cable type: S.W.A., S.T.A. The E-Myth Revisited: Why Most Small Businesses Don't Work and, Harper Lee's To Kill a Mockingbird 50th Anniversary Celebration, Boundaries: When to Say Yes, How to Say No, Shoe Dog: A Memoir by the Creator of Nike, The 5 Love Languages: The Secret to Love that Lasts, An American Marriage (Oprah's Book Club): A Novel, When They Call You a Terrorist: A Black Lives Matter Memoir, Trillion Dollar Coach: The Leadership Playbook of Silicon Valley's Bill Campbell, The Positive Shift: Mastering Mindset to Improve Happiness, Health, and Longevity, 0% found this document useful, Mark this document as useful, 100% found this document not useful, Mark this document as not useful, Save Cable Gland size chart.pdf For Later, recommend that the cable diameter is checked. The EN 60 423 standard lists the individual thread sizes. The previously-known thread sizes PG 7 to PG 48 (10 sizes) were replaced by the metric sizes M 12 to M 63 (8 sizes). 0000009287 00000 n "_գO�;��$V��������ff�/c5[~�4��,�O��l�Տ�aTc����vT�3hm 5�5����d�zD$�_ߛ,�1^A6��'���q�}�yj��c̗gL�C�Y�cն�Ǡ�TX �j���6v�$Z����*���X���qԍ���Ɔ�x貆����B�U�=R1}��x�]��+���TrʞN��l��r���@3 )�2%��|�*�f�����R׿����u�r�\���u~�uqG��o ��� endstream endobj 15 0 obj <>stream H��RMo1��W�qS)��}L����J(��n(��T��{7�"��R|! The gland sizes recommended in this chart are for guidance only and are based on cables manufactured to BS 5467. Cable Glands size chart.
2020 Form 1040 Draft, When Is National Yes Day For Boys, Funny Poems About Dogs, Carthage College Women's Track And Field Roster, Amazon Philippines Office Address, Victorian Electoral Commission Phone Number, December 4th 2020 Weather, Cheap Highball Glasses, Younger Brother In Korean Informal,